Port 1
|
RS232 Full Duplex or
|
|
Port 1
|
RS485 Multi-drop optional or
|
|
Port 1
|
20mA Current Loop optional
|
|
Port 2
|
RS232 Full Duplex, no RTS on COMM 2
|
|
Protocols
|
Modbus
|
|
Baud Rates
|
150 - 58,300K bps
|
|
Custom Transmit Tables
|
4 - user defined RS-232 output tables
|
|
Input Interpreter Tables
|
15 - user defined RS-232 input tables
|
|
|
VFD
|
Bright 6 digit .75" (23.3mm) Vacuum Flourescent (VFD) with 2x5 (10 character) dot matrix for scale status and operator prompting
|
|
|
Signal Input Sensitivity
|
0.1 - 20mV/V
|
|
Signal Connection
|
4 or 6 conductors with sense leads
|
|
Excitation Current
|
350mA, short circuit protected
|
|
Excitation Voltage
|
10 VDC short circuit protected
|
|
Power Requirement
|
AC, 90 - 250VAC, 50/60Hz
|
|
Power Requirement
|
DC, 10 - 32VDC
|
|
Fuse
|
0.8A Slo-Blow (when using AC power)
|
|
|
Keypad
|
Durable elastomeric (rubber), 5 Key (Zero, Print, Units, Tare, Select)
|
|
Stainless Steel
|
Nema 4X, IP66 design
|
|
Shipping Weight
|
7lb.
|
|
|
Full Scale(F.S.)
|
Selectable 0.01 to 999,990
|
|
Resolution
|
20 bit A/D converter, 100,000d(+/-500,000 internal)
|
|
A/D Conversion
|
60Hz
|
|
Flash Memory
|
512k Bytes
|
|
Calibration
|
Selectable, 5 point linearization or enter L.C. mV/V F.S.
|
|
A/D Filtering
|
GSE FIR(Finite Input Response) Filter with selectable display update rate
|
|
Units of Measure
|
4 user defined per scale
|
|
Custom Units
|
2 user defined per scale (i.e.. Tons)
|
|
Zero Adjustment
|
Selectable, 0.01 - 100% F.S.
|
|
Non-Linearity
|
0.005%FS, L.C. Dependent
|
|
Operating Temp
|
-10 Degrees Centigrade - +40 Degrees Centigrade
|
|
Time/Date Clock
|
Volatile, battery backed optional
|
|
Warranty
|
2 year limited
|
|
|
I/O Scan Rate
|
16ms maximum
|
|
Number of I/O
|
8 maximum physical, optional
|
|
Number of I/O
|
16 Total (8 physical, 8 logical)
|
|
Output Voltage Rating
|
20 - 240 VAC @1A
|
|
Output Voltage Rating
|
30 - 60 VDC @2A
|
|
Input Voltage Rating
|
60 - 135 VAC
|
|
Input Voltage Rating
|
200 - 250 VAC
|
|
Input Voltage Rating
|
3 - 30 VDC
|
|
I/O Timer Resolution
|
10mx
|
|
Remote Contact Input
|
2 total for TARE, PRINT, START, STOP, etc.
|
|
Remote Contact Input
|
Invokes macros 6 & 7 if programmed
|
|
|
|
|
 |
|
|
 |
Selectable Weighing Units |
|
|
 |
VFD Display |
|
|
 |
Remote Tar, Print, Zero |
|
|
 |
Panel Mounting |
|
|
 |
AC or DC Operation |
|
|
 |
15 Macros |
|
|
 |
15 Data Registers |
|
|
|
|
| |
 |
|
|
 |
Multi-Scale Module |
|
|
 |
Analog Output Module |
|
|
 |
I/O Relay Module |
|
|
 |
RS485 Module |
|
|
 |
20 mA Current Loop |
|
|
 |
Alpha Keyboard |
|
|
 |
Dura-Shield |
|
|
 |
ReFlash Software |
|
|
 |
DeviceNet |
|
|
 |
Profibus |
|
|
 |
Rabbet Software |
|
|
|
|
| |
 |
|
|
 |
Truck Weighing Programs |
|
|
 |
Checkweighing Routines |
|
|
 |
Parts Counting and Inventory Control |
|
|
 |
Filling and Batching |
|
|
 |
Mult-Range Scale Indication |
|
|
 |
Peak Weight Hold |
|
|
|
|
|